第一个资料:
Windows 10 Event 10016 Fix: The
application-specific permission settings do not grant Local Activation
permission for the COM Server application with CLSID
{D63B10C5-BB46-4990-A94F-E40B9D520160} and APPID
{9CA88EE3-ACB7-47C8-AFC4-AB702511C276} to the user NT AUTHORITY\LOCAL
SERVICE SID (S-1-5-19) from address LocalHost (Using LRPC) running in
the application container Unavailable SID (Unavailable). This security
permission can be modified using the Component Services administrative
tool.I a
Ran into a lot of DCOM (DistributedCOM) errors on Windows 10 machines
after upgrades. Looks like the TrustedInstaller from a previous
application and the RunTime Broker did not give System and Local
Administrators permission during a Windows 10 upgrade. It just an
annoying thing but also slows down a windows 10 Login.
让客户满意是我们工作的目标,不断超越客户的期望值来自于我们对这个行业的热爱。我们立志把好的技术通过有效、简单的方式提供给客户,将通过不懈努力成为客户在信息化领域值得信任、有价值的长期合作伙伴,公司提供的服务项目有:
域名申请、
雅安服务器托管、营销软件、网站建设、
红花岗网站维护、网站推广。
The Error
The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID
{D63B10C5-BB46-4990-A94F-E40B9D520160}
and APPID
{9CA88EE3-ACB7-47C8-AFC4-AB702511C276}
to the user NT AUTHORITY\LOCAL SERVICE SID (S-1-5-19) from address LocalHost (Using LRPC) running in the application container Unavailable SID (Unavailable). This security permission can be modified using the Component Services administrative tool.
Background
It would appear that an Apple application was installed on these
machines at some point and that it did not do a proper install. The W10
upgrade exacerbated the issue due to missing security accounts after a
W10 upgrade. The fix is to give local administrators and System rights
to the DCOM. To do this you have to modify premissions on two registry
keys and then change the DCOM premissions. Pretty easy to do.
FIX
Regedit Take Ownership
You will need to take ownership then set rights against two different keys. The keys are:
HKEY_CLASSES_ROOT\AppID\{9CA88EE3-ACB7-47c8-AFC4-AB702511C276}
HKEY_CLASSES_ROOT\CLSID\{D63B10C5-BB46-4990-A94F-E40B9D520160}
- Open Regedit with Administrators privileges and navigate to the keys above (remember you have to do this twice)
- WinKey + X >> Command Prompt (Admin) >> Type in Regedit
- Right click the key >> permissions
- Click advanced
- At the top change the Owner to COMPUTERNAME\Administrators
- Please note if you are domain joined you’ll have to change where you are searching from to your local computer
- Look in the Permission Entries field
- If the local system administrators group is listed ensure it has full control
- if the administrators group is not listed add it and give it full
control. (note you can only do this if you are a member of the
administrators group and it is now the owner)
- Click okay a lot >> Ensure you apply permissions to all child objects
Change DCOM Permissions
Need to ensure DCOM permissions are setup
- Open DCOMCNFG as an Administrator
- WinKey + X >> Command Prompt (Admin) >> Type in DCOMCNFG
- Navigate to Component Services >> Computers >> My Computer >> DCOM Config
- Find the RunTimeBroker >> Right Click >> Properties >> Security Tab
- Launch and Activation Permissions >> Edit >> Add System and give it full control
- I also added the Administrators group just for testing
While changing permissions I was prompted several times to remove bad
account references. I did this as the computer knows which accounts
have been removed.
Summary
At this point you should have sorted the DCOM errors. Give your computer a reboot and away you can go.
https://shauncassells.wordpress.com/2015/09/28/windows-10-event-10016-fix-the-application-specific-permission-settings-do-not-grant-local-activation-permission-for-the-com-server-application-with-clsid-d63b10c5-bb46-4990-a94f-e40b9d520160-and-a/
第二个资料中文
/tupian/20230522/3550674.html
标题名称:win10eventviewer报错10016系统会重启-创新互联
浏览地址:
http://cxhlcq.com/article/cseddc.html